Nhan đề: | Buckling Analysis and Section Optimum for Square Thin-Wall CFST Columns Sealed by Self-Tapping Screws |
Tác giả: | Zhang, He Wu, Kai Xu, Chao Ren, Lijian Chen, Feng |
Từ khoá: | Tube plate Tapping screws Seams Concrete Concretes Design specifications Tubes Steel plates Computer simulation Strain gauges |
Năm xuất bản: | 2019 |
Nhà xuất bản: | Hindawi Publishing Corporation |
Tóm tắt: | Two columns of thin-walled concrete-filled steel tubes (CFSTs), in which tube seams are connected by self-tapping screws, are axial compression tested and FEM simulated; the influence of local buckling on the column compression bearing capacity is discussed. Failure modes of square thin-wall CFST columns are, first, steel tube plate buckling and then the collapse of steel and concrete in some corner edge areas. Interaction between concrete and steel makes the column continue to withstand higher forces after buckling appears. A large deflection analysis for tube elastic buckling reflects that equivalent uniform stress of the steel plate in the buckling area can reach yield stress and that steel can supply enough designing stress. Aiming at failure modes of square thin-walled CFST columns, a B-type section is proposed as an improvement scheme. Comparing the analysis results, the B-type section can address both the problems of corner collapse and steel plate buckling. This new type section can better make full use of the stress of the concrete material and the steel material; this type section can also increase the compression bearing capacity of the column. |
Mô tả: | 14 tr. |
Định danh: | http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/16090 |
ISSN: | 1687-8086 1687-8094 (e) |
Bộ sưu tập: | Bài báo_lưu trữ |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
BBKH850_TCCN_Buckling Analysis and Section.pdf Giới hạn truy cập | Buckling Analysis and Section Optimum for Square Thin-Wall CFST Columns Sealed by Self-Tapping Screws | 11.01 MB | Adobe PDF | Xem/Tải về Yêu cầu tài liệu |