Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/19088
Toàn bộ biểu ghi siêu dữ liệu
Trường DCGiá trị Ngôn ngữ
dc.contributor.authorZheng, Shuangjie-
dc.contributor.authorChen, Zhao-
dc.contributor.authorLiu, Yangqing-
dc.date.accessioned2020-06-06T13:24:55Z-
dc.date.available2020-06-06T13:24:55Z-
dc.date.issued2019-
dc.identifier.issn1687-8086-
dc.identifier.issn1687-8094 (eISSN)-
dc.identifier.otherBBKH1430-
dc.identifier.urihttp://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/19088-
dc.description"Hindawi Advances in Civil Engineering Volume 2019, Article ID 5952319, 16 pages https://doi.org/10.1155/2019/5952319"vi
dc.description.abstractIn steel and concrete composite structures, it is unfavourable to install many headed studs or perfobond ribs with narrow spacings at the joints. To solve this problem, a new type of a mixed shear connector was developed by combining a headed stud and perfobond rib at the same steel beam flange. In this paper, totally nine push-out tests were conducted. The main purpose was to compare the failure mode and the load-slip behavior of the headed stud, perfobond rib, and mixed shear connector. Furthermore, 19 nonlinear finite element simulations were performed. The effects of connector dimension and material properties on the structural behaviors of mixed shear connectors were studied. Based on the experimental and parametric study, an analytical equation was finally proposed to evaluate the shear capacity of perfobond rib with a headed stud mixed shear connector.vi
dc.language.isoenvi
dc.publisherHindawi Limited,vi
dc.subjectRibs (structural)vi
dc.subjectFinite element methodvi
dc.subjectConstructionvi
dc.subjectInvestigationsvi
dc.subjectMaterial propertiesvi
dc.subjectTension testsvi
dc.subjectConcretevi
dc.subjectFailure modesvi
dc.subjectFailure modesvi
dc.subjectMetal fatiguevi
dc.subjectMetal fatiguevi
dc.subjectSteel beamsvi
dc.subjectStructural steelsvi
dc.subjectCultural heritage; Steel structures"vi
dc.subjectStudsvi
dc.subjectDesign specificationsvi
dc.subjectStructural steelsvi
dc.subjectNumerical analysisvi
dc.subjectShearvi
dc.subjectDesign specificationsvi
dc.subjectEngineeringvi
dc.titleParametric Push-Out Analysis on Perfobond Rib with Headed Stud Mixed Shear Connectorvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH1430_TCCN_Parametric Push-Out Analysis.pdf
  Giới hạn truy cập
Parametric Push-Out Analysis on Perfobond Rib with Headed Stud Mixed Shear Connector9.82 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.