dc.description"Hindawi; Advances in Civil Engineering; Volume 2019, Article ID 1659325, 11 pages; https://doi.org/10.1155/2019/1659325"vi
dc.description.abstractResearch on fire spread in super high-rise buildings is crucial for identifying feasible methods of fire prevention and personnel evacuation. In this study, a fire spread model was established based on the fire dynamics simulator (FDS), and fire spread results were analyzed for a fire scenario in a single room under different conditions, a fire scenario in different functional places under the same conditions, and the spread of fire outside of the room. The results revealed that the critical time required for a fire to become a safety hazard in a shop, a restaurant, or an office was approximately 200 s. The same type of fire reached the critical time required for a fire to become a safety hazard more quickly in an office than a restaurant or shop, regardless of whether the fire spread was caused by CO mass fraction or temperature. More attention should be paid to fire safety in office spaces in super high-rise buildings. Furthermore, compared with CO mass fraction and temperature, visibility was a more influential factor in determining the critical time required for fire to become a hazard, and smoke affected the adjacent open area in approximately 60 s. In the event of a fire, the temperature of the staircase and its front chamber was always lower than the threshold temperature of 60°C for human body tolerance.vi
dc.language.isoenvi
dc.publisherHindawi Limitedvi
dc.subjectResearchvi
dc.subjectFire safetyvi
dc.subjectSmokevi
dc.subjectFire preventionvi
dc.subjectFlooringvi
dc.subjectHigh rise buildingsvi
dc.subjectFire protectionvi
dc.subjectIdentification methodsvi
dc.subjectBuildingsvi
dc.subjectStudiesvi
dc.subjectCommercial spacevi
dc.subjectVisibilityvi
dc.subjectMathematical modelsvi
dc.subjectEngineeringvi
dc.subjectVentilationvi
dc.subjectFeasibility studiesvi
dc.titleNumerical Simulation of Fire Smoke Spread in a Super High-Rise Building for Different Fire Scenariosvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH1410_TCCN_Numerical Simulation of Fire Smoke.pdf
  Giới hạn truy cập
Numerical Simulation of Fire Smoke Spread in a Super High-Rise Building for Different Fire Scenarios5.75 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.