dc.description"Hindawi; Advances in Civil Engineering; Volume 2019, Article ID 7654683, 11 pages; https://doi.org/10.1155/2019/7654683"vi
dc.description.abstractThe phenomenon of hospital functional interruption has been widely observed in the historical moderate-strong earthquakes, indicating that hospital functionality cannot be well considered in the current seismic design methods. The concept of seismic resilience pays enough attention to postearthquake functionality of buildings, and it is particularly significant for the urban hospitals which play critical role in the urban postearthquake rescue and recovery. This study proposes a framework to assess the seismic resilience of urban hospitals, by incorporating the fault tree analysis (FTA) to consider the interdependency between the damage of nonstructural components and the functionality of medical equipment, as well as the effect of external supplies on the functionality of hospital. The proposed framework is then applied to a case-study hospital, and the results indicate that this hospital needs 1.1 days to resume emergency functionality under REDi repair strategy after design basis earthquake (DBE), while it needs 28.8 days to resume emergency functionality under REDi repair strategy after maximum considered earthquake (MCE). It is found that the seismic resilience of this hospital after MCE cannot meet the community requirements on the recovery time, and necessary measures are needed to improve the seismic resilience. The proposed framework provides the quantitative results of seismic resilience assessment in the preearthquake environment and can further support emergency response planning and seismic retrofits strategies.vi
dc.language.isoenvi
dc.publisherHindawi Limitedvi
dc.subjectEmergency medical carevi
dc.subjectEmergency medical servicesvi
dc.subjectFault treesvi
dc.subjectBuildingsvi
dc.subjectEarthquake resistancevi
dc.subjectHospitalsvi
dc.subjectRecoveryvi
dc.subjectEmergency responsevi
dc.subjectAseismic buildingsvi
dc.subjectMedical equipmentvi
dc.subjectFuzzy logicvi
dc.subjectSeismic designvi
dc.subjectCasualtiesvi
dc.subjectPatient safetyvi
dc.subjectUrban health carevi
dc.subjectEmergency preparednessvi
dc.subjectResiliencevi
dc.subjectFailure analysisvi
dc.subjectSeismic responsevi
dc.subjectRepairvi
dc.subjectCivil engineeringvi
dc.subjectEarthquake damagevi
dc.subjectFault tree analysisvi
dc.subjectEarthquakesvi
dc.subjectRetrofittingvi
dc.subjectMethodsvi
dc.subjectSeismic engineeringvi
dc.subjectRecovery timevi
dc.subjectSeismic activityvi
dc.titleA Framework to Assess the Seismic Resilience of Urban Hospitalsvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH1263_TCCN_A Framework to Assess.pdf
  Giới hạn truy cập
A Framework to Assess the Seismic Resilience of Urban Hospitals2.33 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.