Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18493
Toàn bộ biểu ghi siêu dữ liệu
Trường DCGiá trị Ngôn ngữ
dc.contributor.authorJu-Seong, Jung-
dc.contributor.authorLee, Bang Yeon-
dc.contributor.authorKang-Seok, Lee-
dc.date.accessioned2020-05-30T02:45:46Z-
dc.date.available2020-05-30T02:45:46Z-
dc.date.issued2019-
dc.identifier.issn1687-8086-
dc.identifier.issn1687-8094 (eISSN)-
dc.identifier.otherBBKH1215-
dc.identifier.urihttp://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18493-
dc.descriptionAdvances in Civil Engineering; New York Vol. 2019, (2019)vi
dc.description.abstractIt is very important to investigate the effects of the seismic performance of corrosion-damaged reinforced concrete (RC) members, in terms of their strength and lateral deformability, on the seismic performance of entire building systems. Such investigation allows accurate evaluation of the seismic performance of RC structures with corroded members, including beams and columns. However, current techniques for evaluating the seismic performance of existing RC structures do not take the effects of deterioration (including the corrosion of reinforcing bars) on the performance of RC members into account. The main objective of this research is to propose a practical methodology for evaluating the seismic performance of RC buildings with corrosion-damaged members. We extrapolate a structural performance degradation factor from the strength-deformation capability of corroded members to allow direct quantitative evaluation of their seismic performance. In this study, as a first step toward achieving this goal, we experimentally investigated the effect of reinforcing bar corrosion on the behavior of RC beams and the structural performance degradation factor. Our analysis was based on the strength-deformation capabilities of corrosion-damaged beams. We also propose a relationship between the half-cell potential of corroded reinforcing bars and the structural performance degradation behavior of RC beams. Our results indicate that there is a relatively strong correlation between the performance degradation factor and the average potential difference, with coefficients of determination (R2) of the flexural and shear beams of 0.78 and 0.91, respectively. The potential difference, which was measured using the half-cell measurement method, can serve as one of the indicators of relative structural degradation, but we must ensure that the environmental measurement conditions are held constant.vi
dc.language.isoenvi
dc.publisherHindawi Limitedvi
dc.subjectMechanical propertiesvi
dc.subjectFormabilityvi
dc.subjectPerformance evaluationvi
dc.subjectColumnsvi
dc.subjectConcretevi
dc.subjectAseismic buildingsvi
dc.subjectDamage assessmentvi
dc.subjectBuilding constructionvi
dc.subjectCorrosionvi
dc.subjectRebarvi
dc.subjectChloridevi
dc.subjectReinforced concretevi
dc.subjectFailure analysisvi
dc.subjectSeismic responsevi
dc.subjectCorrosion effectsvi
dc.subjectBeamsvi
dc.subjectCivil engineeringvi
dc.subjectDeformationvi
dc.subjectEarthquakesvi
dc.subjectPerformance degradationvi
dc.subjectSeismic engineeringvi
dc.titleExperimental Study on the Structural Performance Degradation of Corrosion-Damaged Reinforced Concrete Beamsvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH1215_TCCN_Experimental Study on the Structural.pdf
  Giới hạn truy cập
Experimental Study on the Structural Performance Degradation of Corrosion-Damaged Reinforced Concrete Beams10.12 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.