Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18388
Toàn bộ biểu ghi siêu dữ liệu
Trường DCGiá trị Ngôn ngữ
dc.contributor.authorZhao, Guomin-
dc.contributor.authorLi, Min-
dc.contributor.authorJian, Lv-
dc.contributor.authorHe, Zhicheng-
dc.contributor.authorJin, Shuang-
dc.date.accessioned2020-05-28T01:52:53Z-
dc.date.available2020-05-28T01:52:53Z-
dc.date.issued2018-
dc.identifier.issn1687 - 8086-
dc.identifier.otherBBKH1034-
dc.identifier.urihttp://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18388-
dc.description"Hindawi Advances in Civil Engineering Volume 2018, Article ID 2623741, 7 pages https://doi.org/10.1155/2018/2623741"vi
dc.description.abstractBecause of increasing energy consumption and severe air pollution in China, solar photovoltaic power generation plants are being deployed rapidly. Owing to various factors such as technology, construction, and imperfection of construction standards, solar photovoltaic systems have certain fire risks. This paper focuses on the fire risks of building-integrated solar photovoltaic buildings, as well as temperature and heat flow density near a photovoltaic system in a fire. Based on FDS simulation results, the influence of different building fires on photovoltaic systems is analysed. It is found that the influence of fire on photovoltaic systems installed on a building with a flat roof is stronger than that on a system installed on a building with a sloping roof; the influence of fire on a photovoltaic system installed on a building with external wall thermal insulation is stronger than that on a system installed on a building without such insulation; and in the presence of a skylight, a photovoltaic system installed on a building with a sloping roof is more dangerous.vi
dc.language.isoenvi
dc.publisherHindawi Limitedvi
dc.subjectResearchvi
dc.subjectRoofingvi
dc.subjectConstructionvi
dc.subjectSolar energyvi
dc.subjectBuildingsvi
dc.subjectTemperaturevi
dc.subjectThermal insulationvi
dc.subjectPorous materialsvi
dc.subjectFlat roofsvi
dc.subjectHeat transmissionvi
dc.subjectPhotovoltaic cellsvi
dc.subjectSolar coronavi
dc.titleAnalysis of Fire Risk Associated with Photovoltaic Power Generation Systemvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH1034_TCCN_ Analysis of Fire Risk Associated.pdf
  Giới hạn truy cập
Analysis of Fire Risk Associated with Photovoltaic Power Generation System1.66 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.