dc.contributor.authorTeng, Zhen-chao-
dc.contributor.authorZhao, Tian-jia-
dc.contributor.authorLiu, Yu-
dc.date.accessioned2020-02-14T06:12:21Z-
dc.date.available2020-02-14T06:12:21Z-
dc.date.issued2019-
dc.identifier.issn1687-8086-
dc.identifier.issn1687-8094 (e)-
dc.identifier.otherBBKH807-
dc.identifier.urihttp://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/15434-
dc.description.abstractIn traditional building construction, the structural columns restrict the design of the buildings and the layout of furniture, so the use of specially shaped columns came into being. The finite element model of a reinforced concrete framework using specially shaped columns was established by using the ABAQUS software. The effects of concrete strength, reinforcement ratio, and axial compression ratio on the seismic performance of the building incorporating such columns were studied. The numerical analysis was performed for a ten-frame structure with specially shaped columns under low reversed cyclic loading. The load-displacement curve, peak load, ductility coefficient, energy dissipation capacity, and stiffness degradation curve of the specially shaped column frame were obtained using the ABAQUS finite element software. The following three results were obtained from the investigation: First, when the strength of concrete in the specially shaped column frame structure was increased, the peak load increased, while the ductility and energy dissipation capacity weakened, which accelerated the stiffness degradation of the structure. Second, when the reinforcement ratio was increased in the specially shaped column frame structure, the peak load increased and the ductility and energy dissipation capacity also increased, which increased the stiffness of the structure. Third, when the axial compression ratio was increased in the structure, the peak load increased, while ductility and energy dissipation capacity reduced, which accelerated the degradation of structural stiffness.vi
dc.language.isoenvi
dc.publisherHindawi Publishing Corporationvi
dc.subjectSoftwarevi
dc.subjectFinite element methodvi
dc.subjectConcretevi
dc.subjectAseismic buildingsvi
dc.subjectSeismic analysisvi
dc.subjectDuctilityvi
dc.subjectReinforced concretevi
dc.subjectSeismic responsevi
dc.subjectFurniturevi
dc.subjectCompressive strengthvi
dc.titleAnalysis of the Seismic Performance of a Two-Span Specially Shaped Column Framevi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH807_TCCN_Analysis of the Seismic.pdf
  Giới hạn truy cập
Analysis of the Seismic Performance of a Two-Span Specially Shaped Column Frame1.88 MBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.