Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này:
http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/15112
Nhan đề: | Container Closure Integrity Testing of Finished Sterile Injectable Product |
Tác giả: | Duncan, Derek |
Từ khoá: | Good Manufacturing Practice Manufacturing Process controls Science Defects Test methods Pharmaceutical industry |
Năm xuất bản: | 2019 |
Nhà xuất bản: | MultiMedia Healthcare Inc. |
Tóm tắt: | Note that, quite generally, a container that is gas-tight will also be tight against microbial ingress. [...]the requirement to maintain headspace gas conditions imposes higher standards on CCI than the requirement to maintain sterility. Test method parameters are optimized during method development and confirmed during validation. [...]a final leak test method is specific to a particular container-closure or product-package system." The framework described in the chapter is currently driving changes in industry best practices for CCI testing, including: * Implementation of a 'toolbox' of CCI test methods optimized and chosen on a per product configuration basis rather than the application of a single legacy test method in a one-size-fitsall approach * Generation of science-based CCI data in robust method validation studies, which demonstrate the detection of a critical leak represented by various types of positive controls. New concepts introduced in the regulatory guidance are changing industry best practices and include the following: * Generate science-based CCI data throughout the product lifecycle to build up a package integrity profile database that can be used as input for risk management. * When possible, use deterministic CCI test methods that have been validated to detect a critical leak. * There is no one-size-fits-all CCI test; a toolbox of CCIT technologies that can be optimized on a per-product package configuration is necessary for a robust CCIT program. Because industry best practices will be evolving as the impact of new guidance becomes clearer, a certain amount of uncertainty in CCIT best practices is to be expected in the near term. |
Mô tả: | Pharmaceutical Technology. Vol 43 (September 2019) |
Định danh: | http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/15112 |
ISSN: | 1543-2521 2150-7376 (e) |
Bộ sưu tập: | Bài báo_lưu trữ |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
BBKH672_TCCN_Container Closure Integrity.pdf Giới hạn truy cập | Container Closure Integrity Testing of Finished Sterile Injectable Product | 366.81 kB | Adobe PDF | Xem/Tải về Yêu cầu tài liệu |