Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này: http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/12626
Toàn bộ biểu ghi siêu dữ liệu
Trường DCGiá trị Ngôn ngữ
dc.contributor.authorCarlos, Montalvo-
dc.contributor.authorClaudia, Aguilar-
dc.contributor.authorLozano, b Cantú-
dc.contributor.authorDenis-
dc.contributor.authorJulia, Cerón-
dc.contributor.authorRosa, Cerón-
dc.contributor.authorAtl, Córdova-
dc.contributor.authorMontalvo-
dc.date.accessioned2019-11-20T04:18:33Z-
dc.date.available2019-11-20T04:18:33Z-
dc.date.issued2015-
dc.identifier.issn2348 - 7968-
dc.identifier.otherBBKH567-
dc.identifier.urihttp://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/12626-
dc.descriptionIJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 1, January 2015 Vol. 2 Issue 2, 7p.vi
dc.description.abstractThe mass transfer coefficient of oxygen (kL.a) was determined for biofilms produced in a rotating biological contactor (RBC) by means of a microelectrode built at the laboratory. Three different rotational velocities (1.25, 2.75 and 5.25 rpm) were used for the determination. The microelectrode tip was made of platinum (99% purity); which was mechanically filed down from its initial diameter of 0.5 mm to 67 μm. The microelectrode was then mounted on a micromanipulator with a precision of 100 μm. The RBC was fed with municipal wastewater, reaching a removal efficiency of 65% as soluble COD and 96% removal of nitrogen as ammonia nitrogen (N-NH4). The hydraulic retention time (HRT) was 8 h. The average room temperature was 26.7 °C and the water temperature in the RBC was constant (22 °C) during the measurement. The kL.a determined at 1.25 rpm was 1.953 (day)-1, while that determined at 2.75 rpm was 3.117 (day)-1 and finally at 5.25 rpm was 9.799 (day)-1. The results confirmed the irregularity of the biofilm’s structure.vi
dc.language.isoenvi
dc.subjectMass transfervi
dc.subjectCoefficientvi
dc.subjectMicroelectrodevi
dc.subjectBiodiskvi
dc.subjectBiofilmsvi
dc.titleMass Transfer Coefficient (kL.a) Determination With Microelectrodes In Biofilms From An RBC At Different Operation Conditionsvi
dc.typeOthervi
Bộ sưu tập: Bài báo_lưu trữ

Các tập tin trong tài liệu này:
Tập tin Mô tả Kích thước Định dạng  
BBKH567_TCCN_264.Mass Transfer Coefficient.pdf
  Giới hạn truy cập
Mass Transfer Coefficient (kL.a) Determination With Microelectrodes In Biofilms From An RBC At Different Operation Conditions308.37 kBAdobe PDFXem/Tải về  Yêu cầu tài liệu


Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.